Pulsar PG8098 Anleitung zur Fehlerbehebung

Stöbern Sie online oder laden Sie Anleitung zur Fehlerbehebung nach Nein Pulsar PG8098 herunter. Pulsar PG8098 Troubleshooting guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 5
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SECTION B TROUBLESHOOTER’S GUIDE
PROBLEM
CAUSE SOLUTION
Insufficient water flow to
chlorinator
Check water flow through spray nozzles Clean spray nozzles with compressed air
Inlet Shutoff Valve closed Open Inlet Shutoff Valve
Emergency Shut Off Switch in closed position If ESS Valve is stuck, lower gently to reset
Solenoid Valve not operating properly Check with Dealer
Insufficient chlorine in pool Feed rate/output too low Increase feed rate/output on timer or ORP unit
Chlorinator empty Refill Briquette Tank with Pulsar
® Plus Briquettes
No/low inlet water flow See insufficient water flow section
Outlet Shutoff Valve closed Open Outlet Shutoff Valve
Clogged Discharge Tubing Refer to Section A or Replace discharge tubing
Briquettes stuck together Tap side of Briquette Tank to loosen
Clogged Briquette Tank Grid Refer to Section A
Clogged Venturi System Remove and soak in dilute Pulsar® Acid cleaner 50
Excess chlorine in pool Automatic Controller Problem Refer to automatic controller manual
Feed rate/output too high Decrease feed rate/output on timer
Air leaks Discharge Tubing not properly installed in fittings Reinstall Discharge Tubing
Discharge Valve seat failure Replace Discharge Valve Arm.
Scale prevents Discharge Valve from properly
seating
Remove Discharge Valve Assembly and soak in
dilute Pulsar® Acid Cleaner 50 to remove scale
Pinched O-rings in Tubing Connectors Inspect O-rings on discharge side of feeder
Chlorinator overflow Discharge Tubing clogged Refer to Section A or Replace Discharge tubing.
Insufficient outlet suction Check with Dealer
Emergency overflow switch failure Check with Dealer
Seitenansicht 0
1 2 3 4 5

Inhaltsverzeichnis

Seite 1 - ® Plus Briquettes

SECTION B TROUBLESHOOTER’S GUIDE PROBLEM CAUSE SOLUTION Insufficient water flow to chlorinatorCheck water flow through spray nozzles Clean

Seite 2

1IntroductionGeneral OverviewThe purpose of this guide is to familiarizeinstallation and maintenance personnel with theelectrical functions of the Pul

Seite 3 - Timer Settings:

2Solenoid/Timer Assembly:The Solenoid/Timer Assembly consists of thetimer module which is plugged into the solenoidactuated water valve. Timer Mod

Seite 4 - Troubleshooting Guide

3Troubleshooting Guide Step-by-step Electrical System Test1. Close water inlet and outlet valves2. Verify that the Power transformer is pluggedinto a

Seite 5 - METER TEST

4METER TESTThe following tests should be performed utilizinga volt meter (ref. Fig.5 – detailed schematic &Fig.6 -- meter placement). The followin

Kommentare zu diesen Handbüchern

Keine Kommentare